Melt Flow Index (MFI) & Rheological Analysis

ISO 1133ASTM D1238g/10 min

A masterbatch’s carrier resin must flow compatibly with the polymer on your production line. MFI is the primary way to measure this.

Method

Flow compatibility determines blend quality.

The melt flow index (MFI / MFR) expresses, in grams, the amount of molten polymer that flows through a standard die in 10 minutes at a specified temperature and load (g/10 min). Its volumetric equivalent is the MVR (cm³/10 min).

The difference in flow between the masterbatch and the base polymer directly affects blend homogeneity, color distribution, and process stability. That is why carrier resin selection and MFI control are part of our quality process.

Rheological analyses help us understand the flow behavior of the melt under different conditions and guide formulation selection, especially on thin-film and high-speed lines.

Measurement conditions

Typical test conditions by polymer

PolymerTemperatureLoad
PE190 °C2.16 kg
PP230 °C2.16 kg
PS200 °C5 kg
ABS220 °C10 kg

For other polymers, the conditions of the relevant standard apply.

Why it matters

Benefits of MFI control

  • Blend compatibility: the masterbatch disperses evenly in the melt
  • Process stability: consistent flow from batch to batch
  • Product quality: preventing surface defects and color fluctuations
Process

How is it measured?

  1. Preparation

    Conditioning

    If required, the sample is dried and conditioned.

  2. Heating

    Test temperature

    The sample is brought to the test temperature in the cylinder.

  3. Flow

    Standard load

    The melt flows through the die under a standard weight.

  4. Calculation

    MFI value

    The cut samples are weighed and the flow rate is calculated in g/10 min.

Laboratory

Let’s plan tests and samples for your product.

Share your application and target values; our laboratory will recommend the right product and prepare your sample along with its measurement results.